Three Phase Power Load (Output) Reactor For VFD's

Reference Standards
EN 61558-2-20
Frequency FF & FC
50/60 Hz, 2kHz to 16kHz +/-5%
Thermal Index
T155 / F
Ingress Protection
IP20 to IP32
Impedance
1% Z
Operating Voltage
380 to 550V
Terminal Blocks
Touch Proof Screwless & Stud type
Varnish
Vacuum Pressure Impregnation Processed
Leads Termination
Top, Side, Front or Custom Designed*
Mount Type
Foot or Custom Designed*

Reactor is placed after VFD / Thyristor drive for reduction of harmonics and di/dt effects, and for following benefits:

  • Reduction of harmonics at the motor.
  • Reduction of temperature in motor and it’s significant increase of service life
Product Cat #
Capacity
Current (A)
ML (mm)
MW (mm)
OL (mm)
OW (mm)
H (mm)
Weight Kgs
135-1.5kW-3-00X-00-LI
1.5 KW
4.0
On request
150
100
120
3.1
135-3kW-3-00x-00-LI
3.0 KW
7.0
On request
160
100
160
4.2
135-4kW-3-00X-00-LI
4.0 KW
11.0
On request
160
100
160
4.5
135-7.5kW-3-00x-00-LI
7.5 KW
16.0
On request
160
150
160
6.0
135-10kW-3-00X-00-LI
10.0 KW
21.0
On request
160
200
160
10.0
135-15kW-3-00x-00-LI
15.0 KW
30.0
On request
200
150
250
13.0
135-30kW-3-00X-00-LI
30.0 KW
60.0
On request
250
200
250
19.0
135-45kW-3-00x-00-LI
45.0 KW
95.0
On request
350
320
300
37.0
135-55kW-3-00X-00-LI
55.0 kW
124.0
On request
350
350
300
43.0
135-75kW-3-00x-00-LI
75.0 KW
156.0
On request
350
350
300
46.5
135-90kW-3-00X-00-LI
90.0 KW
180.0
On request
350
350
300
51.0
135-100kW-3-00x-00-LI
100.0 KW
230.0
On request
350
350
300
56.8
135-160kW-3-00X-00-LI
160.0 KW
280.0
On request
500
500
500
150.0
135-200kW-3-00x-00-LI
200.0 KW
400.0
On request
500
500
500
185.0
135-220kW-3-00X-00-LI
220.0 KW
500.0
On request
500
550
500
210.0

Intermittent/ Load specific duty cycle rated reactors can be manufactured on request.
Reactors with % impedance other than above can be manufactured with no MOQ constraints.
Options are with & without Protective enclosure, fan, self-cooled, Skid mount, HRC, Semiconductor fuse can be customized.
The Protective Enclosure with electrostatic coated, Stainless steel, Welded mesh on request

  • ML – Mounting Length
  • MW – Mounting Width
  • OL – Outer Length
  • OW – Outer Width
  • H – Height.
  • Refer to the above product image to correlate the measurement location

Note :
1. All the dimensions are in mm
2. X, XX, * is for product codification based on standard/ custom designed Specification
3. IGES file format/ Dimensional drawing can be sent on request
4. The above Transformer is only for illustration and may vary for optimum structural integrity, and specification.