Reactance Motor Starters
- Home
- Reactance Motor Starters
Brochures
Isolation Transformers
Control Transformers
Industrial Transformers
Reactors / Chokes
Other Transformers
Filters
Reactance Motor Starters
Coilmag’s Control Transformers are Isolation Transformers designed to provide a high degree of secondary voltage stability (regulation) during a brief period of overload condition (also referred to as “inrush current”). These units are also known as Machine Tool Transformers, Industrial Control Transformers or Control Power Transformers
Reference Standards
|
EN 61558-2-20
|
Frequency
|
50 / 60Hz +/-5%
|
Thermal Index
|
T155 / F
|
Ingress Protection
|
IP20 to IP32
|
Voltage drop
|
Start up: 35% of motor voltage
|
Number of start
|
Upto 5 starts per hour
|
Operating Voltage
|
Upto 440V
|
Terminal Blocks
|
Touch Proof Screwless & Stud type
|
Varnish
|
Vacuum Pressure Impregnation Processed
|
Leads Termination
|
Top, Side, Front or Custom Designed*
|
Mount Type
|
Foot or Custom Designed*
|
Start-up time
|
Upto 20 seconds
|
Reactor suitable for load or no-load motors starting. All reactors may be manufactured for light starting,
typical of one step motor starting, or with two or three steps, for heavy starting.
Product Cat #
|
Capacity
|
ML (mm)
|
MW (mm)
|
OL (mm)
|
OW (mm)
|
H (mm)
|
Weight Kgs
|
---|---|---|---|---|---|---|---|
135-1.5kW-3-00X-00-RS
|
1.5 KW
|
Will be provided on request
|
|||||
135-3kW-3-00x-00-RS
|
3.0 KW
|
||||||
135-4kW-3-00X-00-RS
|
4.0 KW
|
||||||
135-7.5kW-3-00x-00-RS
|
7.5 KW
|
||||||
135-10kW-3-00X-00-RS
|
10.0 KW
|
||||||
135-15kW-3-00x-00-RS
|
15.0 KW
|
||||||
135-30kW-3-00X-00-RS
|
30.0 KW
|
||||||
135-45kW-3-00x-00-RS
|
45.0 KW
|
||||||
135-55kW-3-00X-00-RS
|
55.0 kW
|
||||||
135-75kW-3-00x-00-RS
|
75.0 KW
|
||||||
135-90kW-3-00X-00-RS
|
90.0 KW
|
||||||
135-100kW-3-00x-00-RS
|
100.0 KW
|
||||||
135-160kW-3-00X-00-RS
|
160.0 KW
|
||||||
135-200kW-3-00x-00-RS
|
200.0 KW
|
||||||
135-220kW-3-00X-00-RS
|
220.0 KW
|
Intermittent/ Load specific Duty cycle rated reactors can be manufactured on request
Reactors with % impedance other than above can be manufactured with no MOQ constraints..
Options are with & without Protective enclosure, fan, self-cooled, Skid mount, HRC, Semiconductor fuse can be customized.
The Protective Enclosure with electrostatic coated, Stainless steel, Welded mesh on request.
- ML – Mounting Length
- MW – Mounting Width
- OL – Outer Length
- OW – Outer Width
- H – Height.
- Refer to the above product image to correlate the measurement location
Note :
1. All the dimensions are in mm
2. X, XX, * is for product codification based on standard/ custom Designed Specification
3. IGES file format/ dimensional drawing can be sent on request
4. The above Transformer is only for illustration and may vary for optimum structural integrity, and specification.