Harmonics Mitigation Chokes

Coilmag’s Control Transformers are Isolation Transformers designed to provide a high degree of secondary voltage stability (regulation) during a brief period of overload condition (also referred to as “inrush current”). These units are also known as Machine Tool Transformers, Industrial Control Transformers or Control Power Transformers

Reference Standards
EN 61558-2-20
Frequency
50 / 60Hz +/-5%
Thermal Index
T155 / F
Ingress Protection
IP00 to IP32
Impedance
3, 5 & 7% Z
Operating Voltage
380 to 550V
Terminal Blocks
Touch Proof Screwless & Stud type
Varnish
Vacuum Pressure Impregnation Processed
Leads Termination
Top, Side, Front or Custom Designed*
Mount Type
Foot or Custom Designed*
Product Cat # Capacity kW Current (A) ML MW OL OW H Weight Kgs
135-1.5kW-3-00X-00-LI 1.5 4.0 Will be provided on request
135-3kW-3-00x-00-LI 3.0 7.0
135-4kW-3-00X-00-LI 4.0 11.0
135-7.5kW-3-00x-00-LI 7.5 16.0
135-10kW-3-00X-00-LI 10.0 21.0
135-15kW-3-00x-00-LI 15.0 30.0
135-30kW-3-00X-00-LI 30.0 60.0
135-45kW-3-00x-00-LI 45.0 95.0
135-55kW-3-00X-00-LI 55.0 124.0
135-75kW-3-00x-00-LI 75.0 156.0
135-90kW-3-00X-00-LI 90.0 180.0
135-100kW-3-00x-00-LI 100.0 230.0
135-160kW-3-00X-00-LI 160.0 280.0
135-200kW-3-00x-00-LI 200.0 400.0
135-220kW-3-00X-00-LI 220.0 500.0
Product Cat #
Capacity
Current (A)
ML (mm)
MW (mm)
OL (mm)
OW (mm)
H (mm)
Weight Kgs
135-1.5kW-3-00X-00-LI
1.5 KW
4.0
On request
135-3kW-3-00x-00-LI
3.0 KW
7.0
On request
135-4kW-3-00X-00-LI
4.0 KW
11.0
On request
135-7.5kW-3-00x-00-LI
7.5 KW
16.0
On request
135-10kW-3-00X-00-LI
10.0 KW
21.0
On request
135-15kW-3-00x-00-LI
15.0 KW
30.0
On request
135-30kW-3-00X-00-LI
30.0 KW
60.0
On request
135-45kW-3-00x-00-LI
45.0 KW
95.0
On request
135-55kW-3-00X-00-LI
55.0 kW
124.0
On request
135-75kW-3-00x-00-LI
75.0 KW
156.0
On request
135-90kW-3-00X-00-LI
90.0 KW
180.0
On request
135-100kW-3-00x-00-LI
100.0 KW
230.0
On request
135-160kW-3-00X-00-LI
160.0 KW
280.0
On request
135-200kW-3-00x-00-LI
200.0 KW
400.0
On request
135-220kW-3-00X-00-LI
220.0 KW
500.0
On request

Intermittent/ Load specific duty cycle rated reactors can be manufactured on request.
Reactors with % impedance other than above can be manufactured with no MOQ constraints.
Options are with & without Protective enclosure, fan, self-cooled, Skid mount, HRC, Semiconductor fuse can be customized.
The Protective Enclosure with electrostatic coated, Stainless steel, Welded mesh on request.

  • ML – Mounting Length
  • MW – Mounting Width
  • OL – Outer Length
  • OW – Outer Width
  • H – Height.
  • Refer to the above product image to correlate the measurement location

Note :
1. All the dimensions are in mm
2. X, XX, * is for product codification based on standard/ custom designed specification
3. IGES file format/ dimensional drawing can be sent on request
4. The above Transformer is only for illustration and may vary for optimum structural integrity, and specification.