Harmonics Mitigation Chokes
- Home
- Harmonics Mitigation Chokes
Brochures
Isolation Transformers
Control Transformers
Industrial Transformers
Reactors / Chokes
Other Transformers
Filters
Harmonics Mitigation Chokes
Coilmag’s Control Transformers are Isolation Transformers designed to provide a high degree of secondary voltage stability (regulation) during a brief period of overload condition (also referred to as “inrush current”). These units are also known as Machine Tool Transformers, Industrial Control Transformers or Control Power Transformers
Reference Standards
|
EN 61558-2-20
|
Frequency
|
50 / 60Hz +/-5%
|
Thermal Index
|
T155 / F
|
Ingress Protection
|
IP00 to IP32
|
Impedance
|
3, 5 & 7% Z
|
Operating Voltage
|
380 to 550V
|
Terminal Blocks
|
Touch Proof Screwless & Stud type
|
Varnish
|
Vacuum Pressure Impregnation Processed
|
Leads Termination
|
Top, Side, Front or Custom Designed*
|
Mount Type
|
Foot or Custom Designed*
|
Product Cat # | Capacity kW | Current (A) | ML | MW | OL | OW | H | Weight Kgs | |
135-1.5kW-3-00X-00-LI | 1.5 | 4.0 | Will be provided on request | ||||||
135-3kW-3-00x-00-LI | 3.0 | 7.0 | |||||||
135-4kW-3-00X-00-LI | 4.0 | 11.0 | |||||||
135-7.5kW-3-00x-00-LI | 7.5 | 16.0 | |||||||
135-10kW-3-00X-00-LI | 10.0 | 21.0 | |||||||
135-15kW-3-00x-00-LI | 15.0 | 30.0 | |||||||
135-30kW-3-00X-00-LI | 30.0 | 60.0 | |||||||
135-45kW-3-00x-00-LI | 45.0 | 95.0 | |||||||
135-55kW-3-00X-00-LI | 55.0 | 124.0 | |||||||
135-75kW-3-00x-00-LI | 75.0 | 156.0 | |||||||
135-90kW-3-00X-00-LI | 90.0 | 180.0 | |||||||
135-100kW-3-00x-00-LI | 100.0 | 230.0 | |||||||
135-160kW-3-00X-00-LI | 160.0 | 280.0 | |||||||
135-200kW-3-00x-00-LI | 200.0 | 400.0 | |||||||
135-220kW-3-00X-00-LI | 220.0 | 500.0 |
Product Cat #
|
Capacity
|
Current (A)
|
ML (mm)
|
MW (mm)
|
OL (mm)
|
OW (mm)
|
H (mm)
|
Weight Kgs
|
---|---|---|---|---|---|---|---|---|
135-1.5kW-3-00X-00-LI
|
1.5 KW
|
4.0
|
On request
|
|
|
|
|
|
135-3kW-3-00x-00-LI
|
3.0 KW
|
7.0
|
On request
|
|
|
|
|
|
135-4kW-3-00X-00-LI
|
4.0 KW
|
11.0
|
On request
|
|
|
|
|
|
135-7.5kW-3-00x-00-LI
|
7.5 KW
|
16.0
|
On request
|
|
|
|
|
|
135-10kW-3-00X-00-LI
|
10.0 KW
|
21.0
|
On request
|
|
|
|
|
|
135-15kW-3-00x-00-LI
|
15.0 KW
|
30.0
|
On request
|
|
|
|
|
|
135-30kW-3-00X-00-LI
|
30.0 KW
|
60.0
|
On request
|
|
|
|
|
|
135-45kW-3-00x-00-LI
|
45.0 KW
|
95.0
|
On request
|
|
|
|
|
|
135-55kW-3-00X-00-LI
|
55.0 kW
|
124.0
|
On request
|
|
|
|
|
|
135-75kW-3-00x-00-LI
|
75.0 KW
|
156.0
|
On request
|
|
|
|
|
|
135-90kW-3-00X-00-LI
|
90.0 KW
|
180.0
|
On request
|
|
|
|
|
|
135-100kW-3-00x-00-LI
|
100.0 KW
|
230.0
|
On request
|
|
|
|
|
|
135-160kW-3-00X-00-LI
|
160.0 KW
|
280.0
|
On request
|
|
|
|
|
|
135-200kW-3-00x-00-LI
|
200.0 KW
|
400.0
|
On request
|
|
|
|
|
|
135-220kW-3-00X-00-LI
|
220.0 KW
|
500.0
|
On request
|
|
|
|
|
Intermittent/ Load specific duty cycle rated reactors can be manufactured on request.
Reactors with % impedance other than above can be manufactured with no MOQ constraints.
Options are with & without Protective enclosure, fan, self-cooled, Skid mount, HRC, Semiconductor fuse can be customized.
The Protective Enclosure with electrostatic coated, Stainless steel, Welded mesh on request.
- ML – Mounting Length
- MW – Mounting Width
- OL – Outer Length
- OW – Outer Width
- H – Height.
- Refer to the above product image to correlate the measurement location
Note :
1. All the dimensions are in mm
2. X, XX, * is for product codification based on standard/ custom designed specification
3. IGES file format/ dimensional drawing can be sent on request
4. The above Transformer is only for illustration and may vary for optimum structural integrity, and specification.